National Institute for Occupational Safety and Health

Summary

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

Tetraethyl lead is extremely poisonous. Acute or chronic poisoning may occur if inhaled or absorbed through skin [3] .
SAMPLING: 1. 2. 3. 4.
Calibrate each personal sampling pump with a representative sampler in line. Break ends of the sampler immediately before sampling. Attach sampler to personal sampling pump with flexible tubing. Sample at an accurately known flow rate between 0.01 and 1 L/min for a total sample size of 30 to 200 L. Cap the samplers. Pack securely for shipment.
Source: Wikisource

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

Partial breakthrough (effluent = 2.5% of test concentration) occurred after sampling for 240 min at 1.0 L/min from an atmosphere containing 0.156 mg/m 3 tetraethyl lead (as Pb) at 90% RH. Desorption efficiency for eighteen spiked samples in the range 4.3 to 17 μg tetraethyl lead (as Pb) averaged 1.05 with S r = 0.04.