National Institute for Occupational Safety and Health, NIOSH Manual of Analytical Methods… (1994)
“ Breakthrough tests were conducted with a generated test atmosphere at 1.9 ppm with four impregnated charcoal tubes. The sample volume was 120 L. The average collection efficiency in the front sections was 99.8 ± 0.3%. Breakthrough occurred in only two samples indicating 0.6 and 0.2% breakthrough. An additional breakthrough study was conducted with a generated test atmosphere containing 0.34 ppm diborane at a relative humidity of 60 to 70%. ”