National Institute for Occupational Safety and Health, NIOSH Manual of Analytical Methods… (1994)
“ Desorption efficiency studies as performed by OSHA [1] using 6 samples at 3 levels gave a recovery of 99.0% for DETA, 99.2% for EDA, and 99.8% for TETA. The recovery of DETA, EDA, and TETA from samples used in a 15-day storage study was 89, 94, and 91%, respectively. These samples were generated by spiking the amines onto a glass wool plug in front of a sampling tube and drawing approximately 10 liters of air at 80% relative humidity through them. A 30-day storage study conducted by NIOSH [2] showed similar recoveries. ”