National Institute for Occupational Safety and Health,  NIOSH Manual of Analytical Methods… (1994)

“ Calculate concentration, C, of analyte in the air volume sampled, V (L) :
EVALUATION OF METHOD: The methods on which this method was based were validated under NIOSH Contract CDC-99-74-45 [5] . Desorption efficiency was checked by spiking known amounts of the compounds (either neat or in solutions with CS 2) on coconut shell charcoal. Samples were generated for acetone, cyclohexanone, 2-pentanone, and methyl isobutyl ketone by heating a quantity of the liquid to just below its boiling point in a 3-necked, 500-mL round bottom flask.
”
Source: Wikisource

National Institute for Occupational Safety and Health,  NIOSH Manual of Analytical Methods… (1994)

“ Carbon disulfide is toxic and an acute fire and explosion hazard (flash point = -30 °C) ; work with it only in a hood. SAMPLING: 1. 2. 3. 4.
Calibrate each personal sampling pump with a representative sampler in line. Break the ends of the sampler immediately before sampling. Attach sampler to personal sampling pump with flexible tubing.
”
Source: Wikisource