National Institute for Occupational Safety and Health

Summary

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

Analyte, reagent grade. Helium, purified. Hydrogen, prepurified. Air, compressed, filtered.
See SPECIAL PRECAUTIONS SPE CIAL PR ECAU TIO NS: Carbon disulfide is toxic and an acute fire and explosion hazard (flash point = -30 °C) ; work with it only in a hood. W ear appropriate protective clothing and gloves.
SAMPLING: 1. Calibrate each personal sampling pump with a representative sampler tube in line. 2. Break the ends of the sampler tube immediately before sampling. Attach sampler tube to personal sampling pump with flexible tubing. 3.
Source: Wikisource

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

High humidity greatly reduces sampler capacity and breakthrough volume.
INTERFERENCES: None identified.
OTHER METHODS: This method, NMAM 1450, Issue 3 is an updated analytical procedure [5] . This method originally combined and replaced the NMAM 2nd edition Methods S31, S32, S35, S37, S41, S44 through S48, and S51 [3] . Estimated LOD for each analyte is approximately 10 times lower than that of the previous methods.
NIOSH Manual of Analytical Methods (NMAM) , Fourth Edition EST ERS 1: MET HO D 145 0, Issue 3, dated 15 M arch 200 3 - Page 2 o f 6 REAGENTS:
EQUIPMENT:
1.
Source: Wikisource

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

S am pler: glass tube, 7-cm long, 6-mm OD, 4m m ID, flame-sealed ends, containing two sections of activated (600 °C) coconut s hell charcoal (front - 100 mg; back - 50 mg) separated by a 2-m m ureth ane foam plug. A silylated glass wool plug precedes the front section and a 3-m m urethane foam plug follows the back section.
Source: Wikisource