National Institute for Occupational Safety and Health, NIOSH Manual of Analytical Methods… (1994)
“ Analyte, reagent grade. Helium, purified. Hydrogen, prepurified. Air, compressed, filtered. See SPECIAL PRECAUTIONS SPE CIAL PR ECAU TIO NS: Carbon disulfide is toxic and an acute fire and explosion hazard (flash point = -30 °C) ; work with it only in a hood. W ear appropriate protective clothing and gloves. SAMPLING: 1. Calibrate each personal sampling pump with a representative sampler tube in line. 2. Break the ends of the sampler tube immediately before sampling. Attach sampler tube to personal sampling pump with flexible tubing. 3. ”