National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

All of the desorption efficiency, recovery and storage studies have been performed with laboratory spiked sorbent tubes. Sampling was done with ORBO-42 Large sampling tubes, because the 10-mm OD allowed for a reduced pressure drop, which enabled 8-h samples to be collected at 2 L/min. Benzothiazole in the vapor state is adsorbed on the washed XAD-2 of the ORBO-42 Large sampling tube. However, samples taken during field ® studies where high particulate matter was present have shown some benzothiazole on the Teflon prefilters.
Source: Wikisource

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

Forceps. 7. Syringes, 5-, 10-μL, other sizes if needed. 8. Volumetric flasks, 10-mL, 100-mL. 9. Aluminum foil. 10. Refrigerant packs. 11. ORBO-43 sampling tubes (Supelco) SPECIAL PRECAUTIONS: Hexane is highly flammable. Benzothiazole has an irritating odor and is highly toxic by ingestion. Handle in a well ventilated hood and wear protective clothing.
SAMPLING: 1. 2. 3. 4.
Calibrate each personal sampling pump with a representative sampler in line. Sample at an accurately known flow rate of 1.0 to 2.0 L/min for a total volume of 480 to 960 L. Pack securely for shipment in refrigerant packs.
Source: Wikisource