National Institute for Occupational Safety and Health, NIOSH Manual of Analytical Methods… (1994)
“ Coast Engineering Laboratory 40/60 mesh silica gel was the collecting medium. Average recovery was 97.1%, representing a non-significant bias. The concentration of 2-diethylaminoethanol was independently verified using midget bubblers containing 15 mL 2% HCl. Desorption efficiency was 0.964 in the range 0.6 to 2.3 mg per sample. Breakthrough (5% on back section) was not achieved after 5.3 h when sampling an atmosphere containing 88 mg/m 3 2-diethylaminoethanol at 0.2 L/min at 82% relative humidity. ”