Silica gel

Definition and stakes

National Institute for Occupational Safety and Health,  NIOSH Manual of Analytical Methods… (1994)

“ Prepare a calibration graph (peak area or peak height vs. mg of amine per sample) . Determine desorption (DE) at least once for each lot of silica gel used for sampling in the concentration range of interest. Prepare four tubes at each of five levels plus media blanks. a. Measure the amount of silica gel used in the front sorbent section into a vial. b. Inject a known amount (1 to 20 μL) of calibration stock solution, or a dilution there of directly onto the silica gel. c. Cap vial. Allow to stand overnight. ”
Source: Wikisource

National Institute for Occupational Safety and Health,  NIOSH Manual of Analytical Methods… (1994)

“ NOTE: The water in the ultrasonic bath can get hot (ca. 50-60 °C) during the desorption period. Therefore, all vials must be tightly capped to minimize evaporation losses. Neutralize the sample solution as follows: let silica gel particles settle for a few minutes. Transfer a 500-μL aliquot of the supernatant liquid to a clean vial. Add 500 μL 0.3 M KOH. (The pH of the solution should be greater than 10) . Analyze the solutions immediately (steps 12 through 14) . NOTE: Ensure that no silica gel is present when adding KOH to prevent loss of analyte [1] .
CALIBRATION AND QUALITY CONTROL: 9.
”
Source: Wikisource