Eugene R. Kennedy, Ph.D., Thomas J. Fischbach, Ruiguang Song, Ph.D., Peter M. Eller, Ph.D., Stanley A. Shulman, Ph.D., NIOSH/DPSE and R. DeLon Hull, Ph.D., NIOSH/DSHEFS NIOSH Manual of Analytical Methods… (1994)

The physical state of the analyte (i.e., gas, aerosol, vapor, or combination thereof) plays an important factor in the selection of an appropriate sampler. Analytes which can exist in more than one physical state may require a combination of sampling media in one sampler for efficient collection [1] . Where possible, commonly available and easily used samplers should be investigated initially. As the preliminary testing of a sampling method progresses, further modification in the sampling medium or sampler design may be required and may affect the measurement procedure.
Source: Wikisource

Eugene R. Kennedy, Ph.D., Thomas J. Fischbach, Ruiguang Song, Ph.D., Peter M. Eller, Ph.D., Stanley A. Shulman, Ph.D., NIOSH/DPSE and R. DeLon Hull, Ph.D., NIOSH/DSHEFS NIOSH Manual of Analytical Methods… (1994)

After the initial development experiments for the method have been completed and a method has been proposed, the sampling and analysis approach should be evaluated to ensure that the data collected provides reliable, precise, and accurate results. Specifically, the goal of this evaluation is to determine whether, on the average, over a concentration range of 0.1 to 2 times the exposure limit, the method can provide a result that is within ±25% of the true concentration 95% of the time. For simplification, the true concentration is assumed to be represented by an independent method.
Source: Wikisource

Eugene R. Kennedy, Ph.D., Thomas J. Fischbach, Ruiguang Song, Ph.D., Peter M. Eller, Ph.D., Stanley A. Shulman, Ph.D., NIOSH/DPSE and R. DeLon Hull, Ph.D., NIOSH/DSHEFS NIOSH Manual of Analytical Methods… (1994)

In some instances, generation of an analyte may be difficult and even hazardous. As an alternative to direct generation in these cases, samplers may be fortified with an amount of analyte expected to be sampled over a specified period of time at a specific flow rate. When this is necessary, fortification of the sampler by vaporization of a known amount of analyte onto the sampling medium is a more appropriate method, since this approach more closely approximates a generated atmosphere.