National Institute for Occupational Safety and Health

Summary

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

If a single-use disposable template is not used, clean the template between samples to avoid crosscontamination and provide laboratory with a blank wipe of the cleaned template between samples to ensure that no cross-contamination has occurred. 6.
With freshly gloved hand, take one gauze and wet it with isopropanol or methanol (about 3-4 mL for either the 3” x 3” (7.5 cm x 7.5 cm) 12-ply or the 4” x 4” (10 cm x 10 cm) 8-ply cotton gauze wipes) . Alternatively, pre-wet and insert the gauze wipes into the sample containers off-site.
Source: Wikisource

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

Provide enough wipe media from the same lot to cover all required laboratory media blanks, fieldequipment blanks, samples and sample duplicates, and quality control samples. Use gauze in sterile packaging to minimize the chance for cross-contamination which might more easily occur with open bulk packaged cotton gauze. The gauze wipes needed for the laboratory media blanks and QC samples are to be sent to the laboratory in their unopened sterile packages.
Source: Wikisource

National Institute for Occupational Safety and Health NIOSH Manual of Analytical Methods… (1994)

Blotting is suggested in areas so soiled or rough that the threads of the gauze media are continually snagged. NOTE: On areas larger than 100 cm2, more than five passes and blots will be needed. c. Repeat or Serial Wiping: If isopropanol is used for wiping, a serial or repeat wipe sample of the same area with a fresh gauze wipe will improve sampling efficiency. For serial wiping, repeat the wiping procedure described above (APPENDIX 7a or 7b) with a fresh gauze wipe. Place the second gauze wipe into the same shipping container as the first gauze.
Source: Wikisource