STATIC SYSTEM The static pressure system is employed to operate the rate of descent indicator, altimeter, and to supply pressure to the static pressure transducer for instrumentation. The static system is also utilized to provide a differential pressure for the cabin pressure transducer. The static ports used for atmospheric pressure pick-up, are located in the small end of the spacecraft conical section. The static port, used for differential pressure pick-up, is located on the forward surface of the small pressure bulkhead.
Source: Wikisource

by NASA NASA Project Gemini Familiarization Manual

When the solenoid is energized, the butterfly arm is released and rotates by spring tension, closing the suit circuit valve and mechanically opening the secondary oxygen flow rate poppet valves. Opening the poppet valves allows oxygen to flow to each pilot's suit through fixed orifices at a rate of 0.08 +-0.008 lb/min per man (total flow 0.16 lb/min.) . The butterfly arm simultaneously actuates a switch that de-energizes the solenoid, turns off the suit compressor and cabin fan, and illuminates a SECONDARY FLOW RATE lamp on the pilots' center display panel.